Dynamic and static Uninterruptible Power Supply
Dynamic Uninterruptible Power Supply
SMS (Single Module System) 250 kVA Flywheel UPS
- Flywheel kinetic energy storage
- Battery-free single module system (reduced size 1.4 m²/ 250 kVA)
- Installation without climate control (wide temperature range of 0 – 40°C)
- System efficiency: 97%
- Cos φ = 0.9
- High short-circuit current: 14 (nominal current)
- Analogue, SNMP and Modbus connectivity
MMS (Multi Module System) 250 to 7,000 kVA Flywheel UPS
Main characteristics
- Flywheel kinetic energy storage
- 250 – 500 kVA N+1 (iG Series)
- 250 – 1,000 kVA or 750 kVA N+1 (iZ Series)
- Paralleling capability up to 7 UPS (7,000 kVA)
- Installation without climate control (wide temperature range of 0 – 40°C)
- System efficiency: 98 %
- Cos φ = 0.9
- High short-circuit current: 14 (nominal current)
- Analogue, SNMP and Modbus connectivity
top
Static Uninterruptible Power Supply
Single-phase/Single-phase – Line-Interactive
> From 0.35 to 3 kVA
- Automatic Voltage Regulator (AVR)
- System efficiency: 98%
- Superior battery management (SBM™)
- Available in tower and 19-inch rack format
- Analogue, RS232 and SNMP connectivity
- Automatic Voltage Regulator (AVR)
- Wide input voltage window to extend battery life.
- RS232 interface for advanced UPS-PC communication
- Plug and Play technology for simple installation and operation
Single-phase/Single-phase – On-line double conversion
> From 0.7 – 10 kVA
- Paralleling capability up to 3 UPS
- Hot swappable batteries
- Superior battery management (SBM™)
- Available in tower and 19-inch rack format
- RS232 and SNMP connectivity
- Paralleling capability up to 4 UPS
- Manual bypass
- Galvanic isolation, no pollution via the neutral
- Superior battery management (SBM™)
- Analogue, RS232 and SNMP connectivity
- Voltage and Frequency Independent (VFI)
- Hot swappable batteries
- Superior battery management (SBM™)
- Available in tower and 19-inch rack format
- Analogue, USB, RS232 and SNMP connectivity
top
Static Uninterruptible Power Supply
Three-phase/Single-phase – On-line double conversion
> From 5 – 20 kVA
- Single Phase Bypass output
- Superior Battery Management (SBM™)
- Analogue, RS232 and SNMP connectivity
- Cos φ = 0,8
- Paralleling capability up to 4 UPS
- Galvanic isolation
- Superior battery management (SBM™)
- Analogue, RS232 and SNMP connectivity
Three-phase/Three-phase – On-line double conversion – without transformer
> From 10 to 120 kVA
- Cos φ = 1 from 10 to 30 kVA
- Paralleling capability up to 4 UPS
- Superior battery management (SBM™)
- Analogue, RS232, SNMP and Modbus connectivity
- Cos φ = 1 from 10 to 30 kVA
- Paralleling capability up to 4 UPS
- Superior battery management (SBM™)
- Analogue, RS232, SNMP and Modbus connectivity
top
Static Uninterruptible Power Supply
Three-phase/Three-phase – On-line double conversion – with transformer
> From 10 to 600 kVA
- Cos φ = 0,9
- THDi < 2% (without filter, IGBT rectifier)
- Paralleling capability up to 6 UPS
- Zig-Zag galvanic isolation
- No derating on capacitative power
- Stability during load changes
- Short-circuit capability: 2.7 and 4 times the nominal current respectively for ph-ph and ph-N/PE (for 200ms)
- Analogue, RS232, SNMP and Modbus connectivity
- Cos φ = 1
- Paralleling capability up to 8 UPS
- Zig-Zag galvanic isolation
- No pollution via the neutral
- Superior Battery Management
- Analogue, RS232, SNMP and Modbus connectivity
Three-phase/Three-phase – On-line double conversion – Without transformer
> From 10 to 480 kVA
- True redundancy
- Flexible battery configurations (common, group or single battery)
- Decentralised bypass
- Hot swappable
- Flexible UPS modules scalability (up to twelve 40 kVA modules)
- RS232/RS485 and Modbus connectivity